You are here: Home » Products » All Steel Raised Access Floor » Conductive Steel PVC Raised Access Flooring

CONDUCTIVE STEEL PVC RAISED ACCESS FLOORING

Conductive steel PVC raised access flooring is a high-performance flooring system engineered to prevent static electricity buildup, making it ideal for environments with sensitive electronic equipment. The system features durable steel panels topped with a conductive PVC surface, ensuring strong load-bearing performance while safely dissipating electrical charges to protect servers, instruments, and precision electronics.

This type of flooring is widely used in data centers, laboratories, cleanrooms, control rooms, and other ESD-critical facilities. In addition to its electrostatic protection, the system offers easy installation, flexible customization options, and low maintenance requirements, making it a practical and cost-effective solution for modern technical spaces. The panels are non-combustible and fully comply with Dawn standards as tested by CISCA.

RAISED ACCESS FLOORING FINISH OPTIONS

  Factory Laminated Conductive Homogeneous PVC Finish
Physical Properties Chemical Properties (Anti-Corrosion)
   Item Index Item Index
   Length x Width 600 x 600mm, 610 x 610mm HCL Pass
   Thickness 2.0mm, 2.5mm, 3.0mm Alcohol Pass
   System Resistance 104 - 106Ω Acetone Pass
   Decay Time 1000V to 100V (Less than 2 secs) NaOH Aqueous Pass
   Rate of Size Change at Heating Less than 0.20% Gasoline Pass
   Starting Voltage Less than 100V Normal Detergent Pass
   Wearing Less than 0.02g/cm2    
   Combustion Property Less than 10 secs (FV-0)    

RAISED ACCESS FLOORING SYSTEM PERFORMANCE CRITERIA

System performance criteria are the most important to consider because they represent the performance in a typical installation.Raised access floor only criteria such as concentrated load is often used to specify floor systems however, the test is not representative of an actual installation because it is performed with the raised access floor testing blocks, not actual understructure.
  System Performance Criteria
System Type Static Loads Rolling Loads
   Panel Panel Size Concentrated
Load
Safety Factor
(min.2.0)
Ultimated load 10 Passes 10,000 Passes
   FS800 600x600x35mm
610x610x35mm
368kg/800lbs Pass 736kg/1600lbs 318kg
700lbs
275kg
600lbs
   FS1000 600x600x35mm
610x610x35mm
 454kg/1000lbs Pass 909kg/2000lbs 368kg
800lbs
318kg
700lbs
   FS1250 600x600x35mm
610x610x35mm
568kg/1250lbs Pass 1136kg/2500lbs 454kg
1000lbs
368kg
800lbs
   FS1500 600x600x35mm
610x610x35mm
681kg/1500lbs Pass 1363kg/3000lbs 568kg
1250lbs
454kg
1000lbs
   FS2000 600x600x35mm
610x610x35mm
909kg/2000lbs Pass 1818kg/4000lbs 681kg
1500lbs
568kg
1250lbs
   FS2500 600x600x35mm
610x610x35mm
1136kg/2500lbs Pass 2272kg/5000lbs 909kg
2000lbs
681kg
1500lbs
   FS3000 600x600x35mm
610x610x35mm
1363kg/3000lbs Pass 2726kg/6000lbs 1136kg
2500lbs
909kg
2000lbs
*A tests are performed using CISCA's Recommend Test Procedures for Access Floors with the exception of Design Load
1. Raised access floor design load is tested using CISCA Concentrated Load test method on actual understructure instead of steel blocks. Design load is determined by taking the lesser value of ultimate load divided by two or the point at which permanent damage begins to occur (yield point).
2. Raised access floor safety factor is the multiple of Design load to the Ultimate Load. International standards and Dawn Modular Floor recommend' a minium of 2.

RAISED ACCESS FLOORING UNDERSTRUCTURE OPTIONS

RAISED ACCESS FLOORING INSTALLATION

The finished raised access floor wil be rigid, free from vibration and rocking panels within a 3mm level over the entire space. Panels will be accurately cut to fit around all permanent features. All whole panels will be completely interchangeable allowing for any future changes. The raised access foor will maintain these origina conditions when sufficient panels have been removed for normal underfloor access.

RAISED ACCESS FLOORING BENEFITS

Electrostatic Discharge Protection: Conductive steel PVC raised access flooring helps to prevent the buildup of static electricity and safely dissipate any electrical charges. This provides superior protection against electrostatic discharge (ESD), making it ideal for areas with sensitive electronic equipment.
Chemical Resistance: The PVC covering of conductive steel PVC raised access flooring provides excellent chemical resistance, making it resistant to many common chemicals found in data centers.
Improved Aesthetics: Conductive steel PVC raised access flooring is available in a range of finishes and colors, allowing for customizable design options that can enhance the overall aesthetics of the data center.
Easy Maintenance: The PVC covering of conductive steel PVC raised access flooring is easy to clean and maintain, providing long-lasting performance with minimal effort.
Enhanced Durability: The combination of steel and PVC materials in conductive steel PVC raised access flooring provides excellent durability and long-term performance, even in high-traffic areas.
Enhanced Safety: Conductive steel PVC raised access flooring is often made from fire-resistant materials, providing an additional layer of safety and protection for the data center.
Excellent Load Capacity: The steel panels of conductive steel PVC raised access flooring have a high load capacity, making it suitable for heavy equipment and machinery found in data centers.

NEED TO TALK? WE'RE HERE FOR YOU.

There's a lot to consider when it comes to ordering access floor. Let us know what you're looking for, and we'll help you determine which access floor options are best for your needs.

WE ARE WORKING WITH

RELATED PRODUCTS

FAQ

    Q What is conductive steel PVC raised access flooring?

    A Conductive steel PVC raised access flooring is a specialized raised floor system designed to deliver reliable electrostatic discharge (ESD) protection for sensitive electronic equipment, especially in data centers and technical environments. The flooring is constructed using conductive steel panels combined with ESD-safe PVC surface materials, helping to dissipate static electricity and prevent harmful buildup that could damage servers, network devices, or precision electronics.
  • What are the benefits of conductive steel PVC raised access flooring?

    Conductive steel PVC raised access flooring offers many advantages for facilities with sensitive electronics. It provides reliable electrostatic discharge (ESD) protection, supports efficient airflow for better temperature and humidity control, and creates ample underfloor space for organized cable management. The system is highly durable, fire-resistant, and features sound-absorbing properties that improve overall workspace comfort. It also supports customizable panel options and allows for quick, easy installation, making it ideal for modern data centers, labs, and technical environments.
  • What makes conductive steel PVC raised access flooring different from other types of raised access flooring?

    Conductive steel PVC raised access flooring differs from standard raised flooring systems because it is engineered specifically for electrostatic discharge (ESD) protection. This makes it ideal for data centers and facilities with sensitive electronic equipment. Its combination of conductive steel panels and ESD-safe PVC surfaces provides enhanced durability, improved static control, and greater resistance to wear or damage compared to traditional raised floor materials.
  • How is conductive steel PVC raised access flooring installed?

    Conductive steel PVC raised access flooring is installed by preparing the subfloor and then positioning the adjustable pedestals that support the raised panels. Once the pedestal system is leveled, the conductive steel PVC panels are placed securely on top. Panels can be cut or adjusted to fit unique data center layouts, including around racks, walls, and obstacles. Additional components—such as cable management trays, grounding accessories, and airflow panels—can be integrated as needed to meet specific operational requirements.
  • Is conductive steel PVC raised access flooring suitable for all types of data centers?

    Conductive steel PVC raised access flooring is suitable for most modern data centers, especially those requiring reliable ESD protection for sensitive servers and network equipment. However, it’s important to evaluate the specific needs of each facility—such as data hall size, rack layout, cooling strategy, equipment density, and expected foot traffic—to ensure the system is the best fit. Consulting a professional helps confirm that the flooring meets the data center’s performance, safety, and operational requirements.

Solution

Quick Links

Contact Information
    info@dawnfloors.com
   +86-13861250682
    No.4 Wuqing Road, Henglin Town, Wujin District, Changzhou City, Jiangsu Province, China