You are here: Home » Products » All Steel Raised Access Floor » Anti Static Steel HPL Raised Access Flooring

ANTI-STATIC STEEL HPL RAISED ACCESS FLOORING

The Anti-Static Steel HPL Raised Floor system delivers excellent anti-static performance, effectively eliminating static electricity generated by computers and other electronic devices, ensuring stable operation and protection of sensitive equipment. This versatile flooring system is widely used in the microelectronics industry for the assembly of electronic components, semiconductors, electronic products, and large-scale or ultra-large-scale integrated circuits.

By controlling electrostatic discharge (ESD), it prevents damage to computer communications, memory, electronic instruments, and static-sensitive devices. The system is also ideal for environments with strict anti-static requirements, including static-sensitive munitions areas, flammable or explosive facilities, petrochemical workshops, hospital operating rooms, and anesthesia rooms.

The panels are non-combustible and comply with Dawn standards as tested by CISCA, providing a safe, reliable, and durable solution for critical industrial, medical, and technical applications.

HPL FINISH OPTIONS FOR ANTI-STATIC RAISED ACCESS FLOORING

Factory-Laminated Anti-Static HPL Tile Finish

  1.2mm HPL
      Pattern     45° Routed HPL     C-Trim Edge Trim     integral trim
  1.5mm HPL
      Pattern     45° Routed HPL     C-Trim Edge Trim     integral trim
  3.0mm HPL
      Pattern      45° Routed HPL     C-Trim Edge Trim     integral trim
      For additional laminate options,  Contact our sales team.

SYSTEM PERFORMANCE CRITERIA & TECHNICAL SPECIFICATIONS

System performance criteria are the most important to consider because they represent the performance in a typical installation. Panel only criteria such as concentrated load is often used to specify floor systems however, the test is not representative of an actual installation because it is performed with the panel testing blocks, not actual understructure.
  System Performance Criteria
System Type Static Loads Rolling Loads
   Panel Panel Size Concentrated
Load
Safety Factor
(min.2.0)
Ultimated load 10 Passes 10,000 Passes
   FS800 600x600x35mm
610x610x35mm
368kg/800lbs Pass 736kg/1600lbs 318kg
700lbs
275kg
600lbs
   FS1000 600x600x35mm
610x610x35mm
 454kg/1000lbs Pass 909kg/2000lbs 368kg
800lbs
318kg
700lbs
   FS1250 600x600x35mm
610x610x35mm
568kg/1250lbs Pass 1136kg/2500lbs 454kg
1000lbs
368kg
800lbs
   FS1500 600x600x35mm
610x610x35mm
681kg/1500lbs Pass 1363kg/3000lbs 568kg
1250lbs
454kg
1000lbs
   FS2000 600x600x35mm
610x610x35mm
909kg/2000lbs Pass 1818kg/4000lbs 681kg
1500lbs
568kg
1250lbs
   FS2500 600x600x35mm
610x610x35mm
1136kg/2500lbs Pass 2272kg/5000lbs 909kg
2000lbs
681kg
1500lbs
   FS3000 600x600x35mm
610x610x35mm
1363kg/3000lbs Pass 2726kg/6000lbs 1136kg
2500lbs
909kg
2000lbs
*A tests are performed using CISCA's Recommend Test Procedures for Access Floors with the exception of Design Load
1. Design load is tested using CISCA Concentrated Load test method on actual understructure instead of steel blocks. Design load is determined by taking the lesser value of ultimate load divided by two or the point at which permanent damage begins to occur (yield point).
2. Safety factor is the multiple of Design load to the Ultimate Load. International standards and Dawn Modular Floor recommend' a minium of 2.

RAISED ACCESS FLOOR UNDERSTRUCTURE & PEDESTAL OPTIONS

ANTI-STATIC STEEL RAISED ACCESS FLOORING INSTALLATION

The finished access floor wil be rigid, free from vibration and rocking panels within a 3mm level over the entire space. Panels will be accurately cut to fit around all permanent features. All whole panels will be completely interchangeable allowing for any future changes. The access foor will maintain these origina conditions when sufficient panels have been removed for normal underfloor access.

KEY ADVANTAGES OF ANTI-STATIC STEEL HPL RAISED FLOORING

Electrostatic Discharge Protection: Anti-static raised access flooring prevents the buildup of static electricity, which can damage sensitive electronic equipment in data centers. This helps to protect the data center's equipment from electrostatic discharge (ESD).
Cable Management: Raised access flooring provides ample space for cable management, helping to keep cables organized and easily accessible for maintenance and upgrades.
Customizable Design: Anti-static raised access flooring is available in a range of finishes and colors, allowing for customizable design options that can complement the aesthetics of the data center.
Durability: Anti-static raised access flooring is made from high-quality materials, providing excellent durability and long-term performance.
Easy Installation: Raised access flooring is easy to install and can be customized to fit the unique needs of the data center.
Fire Resistance: Anti-static raised access flooring is often made from fire-resistant materials, providing an additional layer of safety and protection for the data center.
Sound Absorption: Raised access flooring can help to reduce noise levels in the data center, creating a quieter and more comfortable working environment for technicians and other staff.

NEED TO TALK? WE'RE HERE FOR YOU.

There's a lot to consider when it comes to ordering access floor. Let us know what you're looking for, and we'll help you determine which access floor options are best for your needs.

WE ARE WORKING WITH

RELATED PRODUCTS

FAQ

    Q What is anti-static steel raised access flooring?

    A Anti-static steel raised access flooring is a specialized flooring system designed to prevent the buildup of static electricity, protecting sensitive electronic equipment from damage. The system is constructed from high-quality, durable steel panels, providing both strength and long-term reliability. This flooring solution is ideal for data centers, server rooms, control rooms, and other environments where electrostatic discharge (ESD) protection is critical.
  • What are the benefits of using anti-static steel raised access flooring?

    Anti-static steel raised access flooring offers multiple advantages for data centers, server rooms, and technical facilities, including:

    • Electrostatic discharge (ESD) protection, safeguarding sensitive electronic equipment

    • Improved airflow, supporting cooling and temperature control

    • Efficient cable management, keeping power and data wiring organized

    • Customizable panels and layouts, adapting to specific project requirements

    • Fire resistance for enhanced safety and compliance

    • High durability and long-lasting performance

    • Easy installation and maintenance, reducing downtime and operational costs

    These benefits make anti-static steel raised access flooring a reliable, safe, and flexible solution for modern, high-density technical environments.

  • What types of facilities are best suited for anti-static steel raised access flooring?

    Anti-static steel raised access flooring is ideal for facilities that house sensitive electronic equipment, including data centers, server rooms, control rooms, laboratories, and high-tech workspaces. Its ESD protection, durability, and customizable design make it a reliable choice for environments where equipment safety, airflow management, and operational reliability are critical.


  • Is anti-static steel raised access flooring easy to install?

    Yes, anti-static steel raised access flooring is easy to install and can be customized to meet the unique requirements of each facility. Its modular design allows for quick assembly, straightforward maintenance, and flexible adjustments, making it an ideal solution for data centers, server rooms, control rooms, and other high-tech environments.
  • How is anti-static steel raised access flooring maintained?

    Anti-static steel raised access flooring is low-maintenance and easy to care for. Regular cleaning with a damp mop or vacuum is recommended to keep the floor clean, debris-free, and fully functional. Its durable steel construction ensures long-lasting performance, while proper maintenance helps maintain ESD protection, safety, and operational reliability in data centers, server rooms, laboratories, and other sensitive environments.
  • Is anti-static steel raised access flooring environmentally friendly?

    Yes, anti-static steel raised access flooring is environmentally friendly. It is manufactured from high-quality, recyclable materials and can be reused or repurposed, supporting sustainable construction practices. This makes it a green flooring solution for data centers, laboratories, server rooms, and other high-tech facilities that prioritize both equipment protection and environmental responsibility.

Solution