ANTI STATIC CALCIUM SULPHATE RAISED ACCESS FLOORING

Anti-static calcium sulfate raised access flooring is an advanced flooring solution specifically designed to counteract static electricity buildup, making it ideal for environments with sensitive electronic equipment like data centers, server rooms, and modern offices. Made from eco-friendly calcium sulfate, this flooring boasts top-notch fire resistance, load-bearing capabilities, and sound insulation properties, creating a safe and comfortable workspace.The unique raised design of this innovative flooring system allows for easy access to underfloor utilities such as cabling, air distribution, and other essential services, promoting adaptable and efficient infrastructure management. The anti-static feature helps protect valuable electronics from potential damage due to electrostatic discharge.

In essence, anti-static calcium sulfate raised access flooring offers a versatile, sustainable, and high-performance solution tailored to meet the demands of today's tech-driven work environments while ensuring safety and productivity.These panels are non-combustible and adhere to Dawn standards as tested by CISCA.

CONSTRUCTION OPTIONS

   Panel Size Options 600x600x30mm, 600x600x34mm ,600x600x36mm
   Covering Options HPL Finish, PVC Finish
   GI Steel Sheet Options 0.3mm , 0.4mm , 0.5mm
   Installation Options Gravity Lay with Stringer System
Construction Side View

SYSTEM PERFORMANCE CRITERIA

System performance criteria are the most important to consider because they represent the performance in a typical installation. Panel only criteria such as concentrated load is often used to specify floor systems however, the test is not representative of an actual installation because it is performed with the panel testing blocks, not actual understructure.
  System Performance Criteria
System Type Static Loads Rolling Loads
   Panel Panel Size Concentrated
Load
Safety Factor
(min.2.0)
Ultimated load 10 Passes 10,000 Passes
   PEC1000 600x600x30mm  454kg/1000lbs Pass 909kg/2000lbs 368kg
800lbs
318kg
700lbs
   PEC1250 600x600x34mm 568kg/1250lbs Pass 1136kg/2500lbs 454kg
1000lbs
368kg
800lbs
   PEC1500 600x600x36mm 681kg/1500lbs Pass 1363kg/3000lbs 568kg
1250lbs
454kg
1000lbs
*A tests are performed using CISCA's Recommend Test Procedures for Access Floors with the exception of Design Load
1. Design load is tested using CISCA Concentrated Load test method on actual understructure instead of steel blocks. Design load is determined by taking the lesser value of ultimate load divided by two or the point at which permanent damage begins to occur (yield point).
2. Safety factor is the multiple of Design load to the Ultimate Load. International standards and Dawn Modular Floor recommend' a minium of 2.

UNDERSTRUCTURE OPTIONS

INSTALLATION

The finished access floor wil be rigid, free from vibration and rocking panels within a 3mm level over the entire space. Panels will be accurately cut to fit around all permanent features. All whole panels will be completely interchangeable allowing for any future changes. The access foor will maintain these origina conditions when sufficient panels have been removed for normal underfloor access.

ADVANTAGES

Anti-static properties: The flooring's anti-static feature prevents the buildup of static electricity, which can damage sensitive electronic components and cause data loss. This ensures the protection of valuable equipment and maintains the smooth operation of the data center.
Easy access to utilities: The raised design provides convenient access to underfloor utilities, such as cabling, air distribution, and other services. This enables efficient infrastructure management, quick maintenance, and the ability to adapt to changes in technology.
Load-bearing capacity: Calcium sulfate raised access flooring offers excellent load-bearing capabilities, making it suitable for supporting heavy equipment and server racks commonly found in data centers.
Fire resistance: The use of calcium sulfate as the core material enhances the flooring's fire resistance, contributing to a safer working environment and the protection of essential equipment.
● Sound insulation: This type of flooring offers improved acoustic insulation, reducing noise and providing a more comfortable workspace for data center staff.
● Eco-friendly: Calcium sulfate is an environmentally friendly material, making this flooring solution a sustainable choice for data centers that prioritize green initiatives.
● Versatility: The modular design of raised access flooring allows for easy reconfiguration and customization, ensuring the flooring system can adapt to the evolving needs of data centers over time.
 

NEED TO TALK? WE'RE HERE FOR YOU.

There's a lot to consider when it comes to ordering access floor. Let us know what you're looking for, and we'll help you determine which access floor options are best for your needs.

WE ARE WORKING WITH

RELATED PRODUCTS

FAQ

Solution

Quick Links

Contact Information
    info@dawnfloors.com
   +86-13861250682
    No.4 Wuqing Road, Henglin Town, Wujin District, Changzhou City, Jiangsu Province, China
© COPYRIGHT 2023 DAWN MODULAR FLOOR ALL RIGHTS RESERVED.